Implementation of an optical coherence tomography system for painting characterization 

Hannah U. K. S. Kashyapa, b, Cláudia C. B. O. Motab,  Bernardo B. C. Kyotokub, Plínio B. Santos-Filhoc, and Anderson S. L. Gomesb

 

a) Photonova Inc, 110 Elm Crescent, Baie D'Urfé (QC) H9X 2P6, Canada.

b) Department of Physics. Universidade Federal de Pernambuco, Cidade Universitária

50670-901, Recife, PE, Brazil;  anderson@df.ufpe.br

c) Agency for Studies and Heritage Repair, Jardim Atlântico 52050-250, Olinda, Brazil.

† Corresponding author

 

 

 

Abstract. Optical Coherence Tomography (OCT) is a new but well established imaging technique for medical diagnosis, which can produce two- or three-dimensional images of bio-tissues with a few μm spatial resolution. Its potential as a non-invasive tool for art conservation of paintings and other objects has been realized recently. In this work, we report the implementation of two OCT systems applied to painting characterization. One system operates in the so-called spectral domain, with a central wavelength of 840 nm and axial resolution of 10μm. The second system has its central wavelength at 1280 nm, with spatial resolution of 20μm, and operates in the time domain. Both systems are independently controlled and have imaging software developed in-house using LabView. Using both systems, a 15 years old acrylic portrait has been analyzed, where the paint layers, light and dark colors, and the cotton threads of the canvas could be identified.

 

Sumario. La tomografía de coherencia óptica (OCT) es una técnica nueva, pero bien establecida para hacer imágenes para el diagnóstico médico. Puede producir imágenes de los bio-tejidos en dos o tres dimensiones con una resolución espacial de pocos milímetros. Su potencial como una herramienta no invasiva para la conservación de pinturas de arte y otros objetos se ha realizado recientemente. En este trabajo, se presenta la ejecución de dos sistemas de OCT aplicados a la caracterización de pinturas. Un sistema opera en el denominado dominio espectral, con una longitud de onda central de 840 nm y 10 µm de resolución axial. El segundo sistema tiene su longitud de onda central en 1280 nm, una resolución axial de 20 µm, y opera en el dominio del tiempo. Ambos sistemas son controlados independientemente y usan un software en LabView desarrollado en nuestro laboratorio. 

 

Keywords.  Optical tomography, 42.30.Wb, laser applications 42.62.Cf.